Conettix - Information Transport Solutions | Conettix - AT2000/ATE | 425

Connection monitoring is carried out via adjustable,

cyclic polling between the AT 2000 IP ISDN and the IP

receiver. In this way, faults in the transmission path are

recognized and displayed on both sides. With a polling

rate < 20 s there is constant line monitoring (quasi-

dedicated line), which fulfills all VdS requirements for

class C systems. Report transmission occurs if required.

IP demand-driven connection

(VdS 2465 prot. (IP) without polling)

The AT 2000 IP ISDN permits further IP centers to be

programmed without polling. Transmission occurs if

required. The test call can test the connection to the

receiver (e.g. < 25 h).

IP receiver

The ATE IP ISDN is available as a receiver.

IP connection (Ethernet)

For the Ethernet connection of the AT 2000 IP ISDN, a

category 5 cable or an 8-wire shielded network cable is

required. It is connected to a network connection

(shielded).

ISDN connection

The direct connection is to the ISDN S

0

basic access

with the ISDN-DSS1 protocol.

Primary multiplex connection S2M is not possible.

The AT 2000 IP ISDN communicator for danger alarms

must be connected to the S

0

bus as the first device.

With this connection it is possible for the

AT 2000 IP ISDN to send a message even in the event of

tampering or damage to the bus wiring.

ISDN PTP

The "constant monitoring" layer 1 feature is present by

default for system access.

The max. cable length from network termination NT via

the UAE 8/8 box to the TK system or to the end unit is

1000 m.

ISDN PMP

The "constant monitoring" layer 1 feature is also

required with a multi-system connection.

The max. cable length between network termination

and TK system or end unit is 150 m.

Fire detection technology

Interface according to VDE 0833 part 2 can be provided

optionally.

Parts Included

Type

Qty.

Component

AT 2000 IP ISDN

Housing version

1

AT 2000 IP ISDN installation module

with housing and power supply

AT 2000 IP ISDN

Installation module

1

AT 2000 IP ISDN installation module

for installation in control panel housing

e.g. NZ 300 LSN

Technical Specifications

Housing version and installation module
Current consumption

Standby current

Approx. 216 mA

Ethernet transmission

Approx. 216 mA

ISDN transmission

Approx. 218 mA

Additional current per activat-

ed relay

Approx. 12 mA

Terminal resistance of the primary line 10 kilohm ± 1%
Activation time

> 200 ms

Load on switch contacts

Max. output

30 W/60 VA (ohm resistive load)

Max. voltage

50 V

Ambient temperature

-0 °C to +50 °C

Environmental class

II

Protection category

IP 40

Housing

Dimensions (H x W x D)

366 x 258 x 188 mm

Color

Light gray

Weight

10.0 kg

Power supply

Protection class

I

Mains voltage

230 V (-15% to +10%)

Mains frequency

50 Hz (±10%)

Mains current consumption

200 mA

Batteries (ordered separately) 12 V/2 x 10 Ah

Backup time

Max. 72 hrs.

Ethernet module ATXPort
Transmission

10/100 Mbit/sec

Ordering Information

AT 2000 IP ISDN, housing version

With housing, power supply and

AT 2000 IP ISDN installation module, for trans-

mitting alarm or fault messages via the IP or

ISDN network

4998116432

AT 2000 IP ISDN, installation module

For installation in control panel housing, e.g.

NZ 300 LSN, for transmitting alarm or fault

messages via the IP or ISDN network

ITS-AT2000IP-P

Accessories

Extension fire AT 2000

For provision of the interface between

AT 2000 and smoke detector control panel in

accordance with VDE 0833 Part 2

3902130697

Extension 12 in AT 2000

For extending the AT 2000 with 12 additional

inputs (input lines)

ITS-AT12IN

12 in/out AT 2000 extension

For extending the AT 2000 with 12 additional

inputs (input lines) and 12 outputs (relay con-

tacts)

ITS-AT12IO