background image

Detectors and Accessories | Magnetic Contacts Recessed Mount | 263

MS-LZS Flush-Mount

Magnetic Contact

Features

Conventional flush-mount magnetic contact
VdS class C
Tamper switch
Head-on or parallel flush mounting
Conventional perimeter protection

icConventional magnet contacts are used for opening
surveillance of windows and doors.

Certifications and Approvals

Region

Certification

Europe

CE

MS-LZS

Germany

VdS

G 191100, C MS/MSA-LZS

Installation/Configuration Notes

Installation notes

Installation can be parallel or head-on.

Head-on flush mounting in ferromagnetic materials is

possible with the EG2 flush-mount housing.

The magnet should be fixed in the bore.

1

Contact

2

Magnet

Parts Included

Type

Quant. Component

MS-LZS

1

Recessed mount magnetic contact incl. 6 m

cable

Technical Specifications

Type of installation

Flush, parallel or head-on

Contact

Normally open contact/toggle switch

Permissible contact load

≤ 3 Watt

Switching current

10 A to 100 mA

Switching voltage max.

≤ 30 V_

Switch tolerance

≥ 10

7

Magnet

AlNiCo 500

Switch dimensions

Ø 8 mm x 30 mm

Magnet dimensions

Ø 8 mm x 20 mm

Axial installation distance

5 to 12 mm

Temperature range

-25 °C to 70 °C

Connection cable

6 m, LiYY 4 x 0.14 mm

Protection category

IP68

www.boschsecurity.com

Bosch Security Systems B.V.