Ds938z and zx938z series panoramic pir detectors, Ds938z and zx938z series panoramic, Pir detectors – Bosch 8-Dec User Manual

Page 198

Advertising
background image

190 | Detectors and Accessories | Motion Ceiling Mount

DS938Z and ZX938Z Series

Panoramic PIR Detectors

Features

Motion Analyzer II processing
Motion Monitor
Self-test supervision systems
Changeable mirrors
360° x 18 m (60 ft) diameter pattern
2.5 m to 6 m (8 ft to 18 ft) mounting height

These ceiling mount, 18 m (60 ft) panoramic PIR Detectors
use Motion Analyzer II processing to reduce false alarms.
The series consists of the:

DS938Z Panoramic Detector

ZX938Z Panoramic Detector with POPIT

Several unique self-test features, including Motion Monitor,
provide coverage integrity. Field replaceable mirrored
optics allow them to be mounted on ceilings from 2.5 m to
6 m (8 ft to 18 ft) in height.

Functions

Motion Analyzer II Processing
Motion Analyzer II uses multiple thresholds and timing
windows to analyze timing, amplitude, duration, and
polarity of signals to make an alarm decision. It will not
alarm on extreme levels of thermal and illumination
disturbances caused by heaters and air conditioners, hot
and cold drafts, sunlight, lightning, and moving headlights.
Provides three sensitivity settings.
PIR Supervision
PIR supervision provides trouble output in the event that
PIR circuitry fails.

Motion Monitor
Switch-selectable four or thirty day Motion Monitor
supervision timers provide the detector with the ability to
verify that there is a clear view of the protection area and
that it has not been blocked.
Test Features
Three externally visible high output alarm LEDs visible from
any angle, flash to indicate trouble condition. Internal noise
voltage test pins provide precise pattern location and
background disturbance evaluation using a standard analog
meter.

Certifications and Approvals

Region

Certification

Europe

CE

DS938Z, DS938Z-CHI, and DS938Z-FRA:
89/336/EEC, EN55022: 1998 +A1: 2000
+A2: 2003, EN50130-4: 1996 +A1: 1998
+A2: 2003, EN61000-4-2: 1995 +A1:
1998 +A2: 2001, EN61000-4-3: 2002
+A1: 2003, EN61000-4-4: 1995 +A1:
2000 +A2: 2001, EN61000-4-5: 1995
+A1: 2001, EN61000-4-6: 1996 +A1:
2001 +A2: 2001, EN61000-4-11:1994
+A1: 2001, EN60950-1: 2001 +A11:
2004

Poland

CNBOP

DS938Z

USA

UL

DS938Z: ANSR: Intrusion Detection Units
(UL639)
ZX938Z: ANSR: Intrusion Detection Units
(UL639)

China

CCC

DS938Z: 2002031901000002
DS938Z-CHI: 2004031901000036

Sweden

INTYG

DS938Z only: Nr04-683

Europe

DS938Z complies with EN50131‑1, Grade 2

France

AFNOR

NF, A2P

Bosch Security Systems B.V.

www.boschsecurity.com

5

Advertising