LSN Peripherals | LSN Magnetic Contacts | 351

MSE-LSN B Built-In

Magnetic Contact

Features

LSN flush-mount magnetic contact
VdS class B
Head-on or parallel flush mounting
LSN perimeter protection

Magnetic contacts are used for tear-off surveillance of
doors and windows.

Certifications and Approvals

Region

Certification

Europe

CE

MSE/MSA-LSN B/C

Germany

VdS

G 104502, B MSE/MSA-LSN B

Installation/Configuration Notes

Installation notes

Head-on or parallel flush mounting.

The magnet should be fixed in the bore.

Head-on installation in ferromagnetic materials is

possible with the EG1 flush-mount housing.

1

Contact

2

Magnet

Connecting LSN contacts

Each LSN contact is a physical LSN element (1 out of

127 possible per loop).

The length of LSN contact connection cables must be

included when planning the total line length of the LSN

loop, as LSN technology is incorporated in these

detectors.

Passive coupling elements for joining the connection

cables to the installation cable must be placed as close

as possible to the LSN contacts. The 1 m connection

cable with 2 m LSN cable length is included in the

calculation of the LSN cable length (LSN is carried into

the contacts and back out again).

Connector boxes (optional) are classified as installation

material.

Testing LSN contacts

Reed switch and microswitch functions can be checked

before installation by a high-Ohm multimeter or

continuity checker (for diode paths).

The resistance values are approximate values; a large

change in resistance is significant here.

1

Detector

2

High-Ohm multimeter

Contact open: approx. 3 megaohm

Contact closed: approx. 1 megaohm

Note

Only the intrusion contact can be checked in
this way. The tamper switch of the Class C
magnetic contact can be checked by the LSN
control panel or with the LSN testing device
(software version 3.x onward).

Parts Included

Type

Qty.

Component

MSE-LSN B

1

Built-in magnetic contact

incl. 4 m cable

Technical Specifications

Type of installation

Flush, head-on or parallel

Operating voltage

Max. 33 V_

Reed contacts

Normally open contact

Switch tolerance

≥ 10

7

Magnet

AlNiCo 500

Switch dimension:

Ø 8 mm x 30 mm

Magnet dimension:

Ø 8 mm x 30 mm

Axial installation distance:

≤ 15 mm

Installation distance with EG1

2 to 6 mm

Temperature range

-25 °C to 70 °C

Connection cable:

4 m, LiY(St) Y 4 x 0.14 mm

with screen, exterior Ø 3.2 mm

www.boschsecurity.com

Bosch Security Systems B.V.

6

Advertising