Automatic Battery Testing
The system performs a battery test each time a user arms
the sys-tem, and automatically every four hours. When the
system detects a low capacity back-up battery, it creates a
low battery fault.
Event Memory Recall
Event Memory Recall plays the last 40 system events,
including all alarms, system arming, and system disarming.
If the control panel is partitioned, Event Memory Recall
plays the last 10 system events.
Programmable Ring Burst Time
Telephone ring times might be longer or shorter depending
on the technology in a system. Different timing can cause
control panels to answer calls that should be answered by
an answering machine, fax, or a person. Users can program
the control panel for the correct ring burst time. Adjust the
ring time from 0 ms to 1200 ms in 5 ms increments.
Call Forwarding
The telecommunications provider must offer a call
forwarding option. Users can program call forwarding
modes to operate when the system is armed in the AWAY
Mode.
Call Forward Modes

Immediate On: Redirects all incoming calls to another

number, including mobile phones, pagers, and

answering services. The telephone called first does not

ring.

No Answer: Redirects all incoming calls to another

number when the telephone that was called first is not

answered within 20 seconds. Outgoing calls can still be

made from the first telephone.

Certifications and Approvals

Region

Certification

Europe

CE

A-Tick Supplier Code

N663

New Zealand Telepermit

PTC 211/98/083

Installation/Configuration Notes

Compatibility Information

RF Receivers

RE005E RF Receiver with Outputs

RF Transmitters

RE012E Two-channel Hand-held Transmitter

RE013E Four-channel Hand-held Transmitter

Codepads

CP105A Night Arm Station

CP500AW LED Area Addressable

CP500ALW LCD Area Addressable

CP500PW LED Partitionable

CP516LW LCD

CP516W LED

Modules

MO144 Universal Timer Module

Technical Specifications

Enclosure

Dimensions:

30.6 cm x 26.2 cm x 8.4 cm

(12 in x 10.3 in x 3.3 in)

Packed in carton

Weight:

2.5 kg (5.5 lb)

Environmental Considerations

Relative Humidity:

10% to 95% non-condensing

Temperature (Operating):

0°C to +45°C (+32°F to +113°F)

Power Requirements

Current Draw (Standby):

65 mA

Current Draw (Alarm):

115 mA

Current Draw (with Codepad): 105 mA
Primary:

240 VAC, 18 VAC at 1.3 A from a TF008

Plug Pack

Secondary:

12 VDC, 6 Ah from a rechargeable sealed

lead/acid battery

Trademarks

MS-DOS

®

is a registered trademark of Microsoft Corporation in the United

States and/or other countries.

Ordering Information

CC488P Solution Ultima 880 Control Panel

Includes assembled printed circuit board

(PCB), power connector, EOL resistors, ter-

minals, and battery leads.

CC488P

Accessories

CC808 Direct Link Cable

Cable to connect CC816 Alarm Link Software

(A‑Link) to Solution 862, Solution 880 Ultima,

and Solution 16 Control Panels.

CC808

CC811S Modem Module

Modem module for Solution 862, 880, and Ul-

tima Control Panels for SMS reporting.

CC811S

CC891 Programming Key

Uploads and downloads program settings for

Solution 16, Solution 862, Solution 880, and

Ultima Control Panels.

CC891

Enclosure with Transformer (220 VAC)

Metal enclosure with 220 VAC transformer,

fuse and terminal block, front and rear tamper

switch, and key lock on door.

EDM-ENCL-KIT