Bosch 8-Dec User Manual

Page 145

Advertising
background image

Detectors and Accessories | Motion PIR | 137

Solid State Relays
Solid state relays send silent alarm output signals to
provide a higher level of security and reliability. An external
magnet does not activate the relay. The solid state relay
uses less current than a mechanical relay, providing longer
standby capacity during a power loss.
Draft, Insect, and Small Animal Immunity
The sealed optic chamber provides immunity to drafts and
insects, reducing false alarms. Small animal immunity
reduces false alarms caused by animals less than 4.5 kg
(10 lb), such as rodents.
Remote Self Test
A remote self test initiates when the walk test input
switches to its true state. The alarm relay and alarm LED
activate for four seconds following a successful test. The
trouble relay activates, and the alarm LED flashes following
a failed test.
Input Power Supervision
When the power is lower than 8 V, a low input power trouble
condition activates the trouble relay and causes the LED to
flash. The trouble condition clears automatically when
power reaches or exceeds 8 V.
DIP Switch Programming
The following functions are all programmed using DIP
switch settings:

Remote Walk Test LED

Long and Short Range Select

Trouble Memory
When the walk test input switches to its true state for less
than two seconds, the LED flashes to indicate the most
recent trouble condition. If there is no trouble in memory,
the LED does not flash. After twelve hours, or after the
detector receives a second walk test pulse for two seconds
or less, the LED stops flashing and the trouble memory
clears.

Certifications and Approvals

Region

Certification

Europe

CE

89/336/EEC, EN55022: 1998 +A2: 2003
(CISPR 22: 1997), EN50130-4: 1995
+A2: 2003, EN61000-4-2: 1995 +A2:
2001, EN61000-4-3: 1996 +A1: 2002,
EN61000-4-4: 1995 +A2: 2001,
EN61000-4-5: 1995 +A1: 2001,
EN61000-4-6: 2003, EN61000-4-11:
1994 +A1: 2001, EN60950-1: 2001 1st
edition

EN50131 Tested to EN 50131-1 Grade 2, TS

50131-2-2 August 2004, EN 50130-4, EN
50130-5

Belgium

INCERT

B-509-0051

Poland

TECHOM

128/06

Region

Certification

USA

UL

ANSR: Intrusion Detection Units (UL639),
ANSR7: Intrusion Detection Units Certified
for Canada (cULus)

Italy

IMQ

France

AFNOR

Type 2 (*), NF et A2P (NF 324 - H 58)

China

CCC

2007031901000293

Sweden

INTYG

Nr07-168

the
Netherlands

REQ

07223000/AA/00

The detector is also designed to comply with following standards and ap-

provals.
Australia

C-Tick

Germany

VdS

Schaden-

verhütung

GmbH

G107504, Class B

Norway

FGI

D‑169/07, D‑620/07

Installation/Configuration Notes

Long-range Coverage: 16 m x 21 m (50 ft x 70 ft)

www.boschsecurity.com