LSN Peripherals | LSN Magnetic Contacts | 363

SKA 100 LSN Bolt Contact

Features

Bolt contact in LSN technology
For connecting to an LSN intrusion control panel
VdS class C
LSN perimeter protection

Bolt contacts are used for monitoring the closure of doors.

Certifications and Approvals

Region

Certification

Europe

CE

SKA 100 LSN

Germany

VdS

G 101009, C SKA 100 LSN

Installation/Configuration Notes

Installation notes

Installation is carried out in the door bolt with the bolt

contact being activated by the tongue of the lock. It

should be kept in mind that only the second turn of the

key in the lock actually activates the contact. To make

any necessary adjustments, the bolt contact's operating

spring lever can be bent.

When installing in fire protection doors, please ensure

that no mechanical changes, except for the fastener

bores, are carried out on the door frames.

Connecting LSN contacts

Each LSN contact is a physical LSN element (1 out of

127 possible per loop).

The length of LSN contact connection cables must be

included when planning the total line length of the LSN

loop, as LSN technology is incorporated in these

detectors.

Passive coupling elements for joining the connection

cables to the installation cable must be placed as close

as possible to the LSN contacts. The 1 m connection

cable with 2 m LSN cable length is included in the

calculation of the LSN cable length (LSN is carried into

the contacts and back out again).

Connector boxes (optional) are classified as installation

material.

Testing LSN contacts

Reed switch and microswitch functions can be checked

before installation by a high-Ohm multimeter or

continuity checker (for diode paths).

The resistance values are approximate values; a large

change in resistance is significant here.

1

Detector

2

High-Ohm multimeter

Contact open: approx. 3 megaohm

Contact closed: approx. 1 megaohm

Note

Only the intrusion contact can be checked in
this way. The tamper switch of the Class C
magnetic contact can be checked by the LSN
control panel or with the LSN testing device
(software version 3.x onward).

Parts Included

Type

Qty.

Component

SKA 100 LSN

1

Bolt contact for perimeter doors, with cable

Technical Specifications

Type of installation

Flush

LSN operating voltage

15 V to 33 V

Current consumption

0.4 mA

VdS environmental class

III

Protection category

IP 67

Permissible

ambient temperature

-25 °C to +70 °C

Housing

Material

Steel plate

Color

Gray

www.boschsecurity.com

Bosch Security Systems B.V.

6