Features

Motion Analyzer II processing
Unique address switch settings
Insect and draft immunity
Three sensitivity settings

The wall mount MX934i PIR Intrusion Detector uses Motion
Analyzer II signal processing to reduce false alarms. Alarm
and tamper conditions are transmitted to the control panel
through the two-wire multiplex bus. The detector’s
replaceable and pointable mirrors, three coverage patterns,
and three mounting options provide installation flexibility.

Functions

Motion Analyzer II Processing
Motion Analyzer II uses multiple thresholds and timing
windows to analyze timing, amplitude, duration, and
polarity of signals to make an alarm decision. It tolerates
extreme levels of heat and light disturbances caused by
heaters and air conditioners, hot and cold drafts, sunlight,
lightning, and moving headlights.
Insect and Draft Immunity
The sealed optical chamber provides immunity to drafts and
insects.
Three Sensitivity Settings

Standard Sensitivity: Recommended setting for

maximum false alarm immunity. Tolerates environment

extremes on this setting. Not recommended for long

range or barrier type coverage patterns. The detector is

shipped in Standard Sensitivity mode.

Intermediate Sensitivity: Recommended setting for

any location where an intruder is expected to cover only

a small portion of the protected area. Tolerates normal

environments on this setting. This setting identifies

intruders more accurately.

High Sensitivity: Fast response to intruder signals. For

use in quiet environments where heat and light

fluctuations are not anticipated.

Certifications and Approvals

Region

Certification

Europe

CE

89/336/EEC, 93/68/EEC, EN55022
(1998), EN50130-4: 1995, EN61000-4:
1995, EN61000-4-2: 1995,
EN61000-4-3: 1995, EN61000-4-4:
1995, EN61000-4-5: 1995,
EN61000-4-6: 1996, EN61000-4-11:
1994
73/23/EEC, IEC 60950: 1999

USA

UL

ANSR: Intrusion Detection Units (UL639)

Installation/Configuration Notes

Compatibility Information

Control Panels

Multiplex Expansion Modules

DS7400Xi Series

G Series

DS7430

DS7436

D8125MUX

Note

The DS7400Xi Series Control Panels require
ROM version 1.07 or greater.

Mounting Considerations
Select a location that is most likely to intercept an intruder
moving across the coverage pattern. Ensure the mounting
surface is solid and vibration free. Avoid hot and cold drafts,
windows, moisture, direct or reflected sunlight, and small
animals. The MX934i is not for outdoor mounting.

Note

Misaligning the detector in an optional
mounting bracket can reduce range and