Bosch 8-Dec User Manual

Page 91

Advertising
background image

Accessories for Control Panels and Keypads | Interface Modules | 83

Certifications and Approvals

Region

Certification

Europe

CE

89/336/EEC, EN55022: 1997 +A2:
2002, EN50130-4: 1995 +A1: 1998 +A2:
2003, EN60950: 2000, EN61000-3-2:
2001, EN61000-3-3A1: 2001,
EN61000-4-2: 1995 +A1: 1998 +A2:
2001, EN61000-4-3: 1996 +A1: 1998
+A2: 2000, EN61000-4-4: 1995 +A1:
2001 +A2: 2001, EN61000-4-5: 1995
+A1: 2001, EN61000-4-6: 1996 +A1:
2000, EN61000-4-11: 1994 +A1: 2001

USA

UL

AMCX: Central Station Alarm Units
(UL1610, UL1635), AMCX7: Central
Station Alarm Units Certified for Canada
(cULus), APAW: Police Station Alarm Units
(UL365, UL464), APAW7: Police Station
Alarm Units Certified for Canada (cULus),
APOU: Proprietary Alarm Units (UL1076),
APOU7: Proprietary Alarm Units Certified
for Canada (cULus), NBSX7: Household
Burglar Alarm System Units Certified for
Canada (cULus), UTOU7: Control Units and
Accessories - Household System Type
Certified for Canada (cULus)
UL864, 9th edition

FM
CSFM

7167-1615: 100, 7165-1615: 119,
7170-1615: 145, and 7300-1615:
180 July 2008

NYC-MEA

12-92-E, Vol. XIII and 12-92-E, Vol. 15

France

AFNOR

NF, A2P Type 2 (122000076-05)

Note

FM Approval applies when the DX4020 is used
with the Conettix D6600 Communications
Receiver/Gateway.

Installation/Configuration Notes

Compatibility information

Applications
RPS:

Supported on all compatible control panels.

PC9000:

Supported on the following control panels:

D9412G, D7412G, D7212G, D9112, D7412,

and D7212.

Building Integration

System (BIS) Security

Engine:

Supported on the following SDI bus control panels

(version 6.3 and higher): D9412GV2,

D7412GV2, D7212GV2, D9412G, D7412G, and

D7212G.

CMS 7000:

Supported on DS7400Xi‑CHI Control Panels (op-

tion bus) set at Mode 18 (version 4.10 or higher).

SDI Bus Control Panels (version 6.0 or higher)

D9412GV2, D7412GV2, and D7212GV2

D9412G, D7412G, and D7212G

D9412, D7412, and D7212

D9112

Option Bus Control Panels

DS7400Xi (version 4.10 or higher)

CC7420‑A

DS7220 and DS7240 (version 2.10 or higher)

FPD‑7024

Connection Considerations
The DX4020 uses a standard Category 3 or Category 5 cable
with an RJ‑45 plug to connect to the network, a two-wire
connection from the control panel bus, and two wires that
connect to the control panel or a power supply for DC
power. For 10BASE‑T, use Category 3 or better. For
100BASE‑T, use Category 5 or better.
Mounting Considerations
The DX4020 mounts to the standard three-hole patterns in
supported control panel enclosures. With the D137
mounting bracket, the DX4020 mounts to other enclosures.

Parts Included

Quant.

Component

1

Ethernet network interface module

1

Cable assembly, quick connect

1

Hardware pack

1

Literature - Installation Guide

Technical Specifications

Environmental Considerations

Dimensions:

7.6 cm x 12.7 cm (3 in. x 5 in.)

Operating Temperature:

0°C to +50°C (+32°F to +122°F)

Relative Humidity:

5% to 85% at 30°C (86°F) non‑condensing

Power Requirements

Current:

10Base‑T: 110 mA maximum

100Base‑T: 135 mA maximum

Voltage (Operating):

12 VDC nominal

Ordering Information

Conettix DX4020 Ethernet Network
Interface Module

Creates two‑way communications over Ether-

net networks for compatible control panels.

DX4020

Accessories

AE1 Standard Enclosure (Gray)

Standard gray enclosure with keyed lock.

Measures 35.6 cm x 31.8 cm x 7.6 cm (14 in.

x 12.5 in. x 3 in.).

AE1

www.boschsecurity.com

Bosch Security Systems B.V.

2

Advertising