Emk 46 s z flush-mount magnetic contact – Bosch 8-Dec User Manual

Page 267

Advertising
background image

Detectors and Accessories | Magnetic Contacts Recessed Mount | 259

EMK 46 S Z Flush-Mount

Magnetic Contact

Features

▶ Conventional flush-mount magnetic contact
▶ VdS class C
▶ Tamper switch
▶ Head-on flush mounting
▶ Conventional perimeter protection

Conventional magnet contacts are used for tear-off
surveillance of windows and doors.

Certifications and Approvals

Region

Certification

Europe

CE

EMK 46 S Z

Germany

VdS

G 196041, C EMK 46 S

Installation/Configuration Notes

Installation notes

•

Installation is head-on in door or window frames.

•

Installation can be completed with or without a plastic

sleeve. If no plastic sleeve is used, the components

should be fixed in the bores.

•

Installation in ferromagnetic materials is not

permissible.

•

The supply lines need to be measured electrically

before connection.

1

Contact

2

Magnet

3

Installation offset

Distances diagram

1

Extraction

2

Proximity switch part

Note: If the attached magnets are touching each other, there will

be no tamper zone!

Parts Included

Type

Qty.

Component

EMK 46 S Z

1

Built-in magnetic contact

incl. flange and sleeves

Technical Specifications

Type of installation

Flush, head-on

Permissible operating voltage

Max. 40 V_

Contact type

1-pin (normally) open contact

Permissible contact load

6 VA

Max. 100 V_

Max. 500 mA

Protection category

IP 67

VdS environmental class IV

Permissible

ambient temperature

-25 °C to +70 °C

Housing

•

Material

ABS

•

Color

White

www.boschsecurity.com

Bosch Security Systems B.V.

5