EMK 36 AT LSN Surface-

Mount Magnetic Contact

Features

▶ LSN surface-mount magnetic contact
▶ VdS class B
▶ Parallel mounting
▶ LSN perimeter protection

Magnetic contacts are used for tear-off surveillance of
doors and windows.

Certifications and Approvals

Region

Certification

Europe

CE

EMK 36 AT LSN

Germany

VdS

G 101504, B EMK 36 AT LSN

Installation/Configuration Notes

Installation notes

•

EMK 36 AT LSN installation is parallel.

•

For installation on ferromagnetic materials, the

distance plates must be used.

•

The contacts are generally installed in the door or

window frames with the magnet in the window or the

door. If the door or window is opened less than 1 cm,

the magnetic contact should not be able to detect this.

An opening of more than 3 cm must be detected.

1

Contact

2

Magnet

Distances diagram (parallel mounting)

1

Extraction

2

Proximity switch part

Connecting LSN contacts

•

Every LSN contact is a physical LSN element (1 out of

127 possible per loop).

•

The length of LSN contact connection cables must be

included when planning the total line length of the LSN

loop, as LSN technology is incorporated in these

detectors.

•

Passive coupling elements for joining the connection

cables to the installation cable must be placed as close

as possible to the LSN contacts. The 1 m connection

cable with 2 m LSN cable length is included in the

calculation of the LSN cable length (LSN is carried into

the contacts and back out again).

•

Connector boxes (optional) are classified as installation

material.

Testing LSN contacts

•

Reed switch and microswitch functions can be checked

before installation by a high-Ohm multimeter or

continuity checker (for diode paths).

•

The resistance values are approximate values; a large

change in resistance is significant here.

1

Detector

2

High-Ohm multimeter

Contact open: approx. 3 MOhm

Contact closed: approx. 1 megaohm

Note

Only the intrusion contact can be checked in
this way. The tamper switch of the Class C

www.boschsecurity.com