Mse-lsn b built-in magnetic contact – Bosch 8-Dec User Manual

Page 359

Advertising
background image

LSN Peripherals | LSN Magnetic Contacts | 351

MSE-LSN B Built-In

Magnetic Contact

Features

▶ LSN flush-mount magnetic contact
▶ VdS class B
▶ Head-on or parallel flush mounting
▶ LSN perimeter protection

Magnetic contacts are used for tear-off surveillance of
doors and windows.

Certifications and Approvals

Region

Certification

Europe

CE

MSE/MSA-LSN B/C

Germany

VdS

G 104502, B MSE/MSA-LSN B

Installation/Configuration Notes

Installation notes

•

Head-on or parallel flush mounting.

•

The magnet should be fixed in the bore.

•

Head-on installation in ferromagnetic materials is

possible with the EG1 flush-mount housing.

1

Contact

2

Magnet

Connecting LSN contacts

•

Each LSN contact is a physical LSN element (1 out of

127 possible per loop).

•

The length of LSN contact connection cables must be

included when planning the total line length of the LSN

loop, as LSN technology is incorporated in these

detectors.

•

Passive coupling elements for joining the connection

cables to the installation cable must be placed as close

as possible to the LSN contacts. The 1 m connection

cable with 2 m LSN cable length is included in the

calculation of the LSN cable length (LSN is carried into

the contacts and back out again).

•

Connector boxes (optional) are classified as installation

material.

Testing LSN contacts

•

Reed switch and microswitch functions can be checked

before installation by a high-Ohm multimeter or

continuity checker (for diode paths).

•

The resistance values are approximate values; a large

change in resistance is significant here.

1

Detector

2

High-Ohm multimeter

Contact open: approx. 3 megaohm

Contact closed: approx. 1 megaohm

Note

Only the intrusion contact can be checked in
this way. The tamper switch of the Class C
magnetic contact can be checked by the LSN
control panel or with the LSN testing device
(software version 3.x onward).

Parts Included

Type

Qty.

Component

MSE-LSN B

1

Built-in magnetic contact

incl. 4 m cable

Technical Specifications

Type of installation

Flush, head-on or parallel

Operating voltage

Max. 33 V_

Reed contacts

Normally open contact

Switch tolerance

≥ 10

7

Magnet

AlNiCo 500

Switch dimension:

Ø 8 mm x 30 mm

Magnet dimension:

Ø 8 mm x 30 mm

Axial installation distance:

≤ 15 mm

Installation distance with EG1

2 to 6 mm

Temperature range

-25 °C to 70 °C

Connection cable:

4 m, LiY(St) Y 4 x 0.14 mm

with screen, exterior Ø 3.2 mm

www.boschsecurity.com

Bosch Security Systems B.V.

6

Advertising