Dx2010 series input expander, Expansion modules – Bosch 8-Dec User Manual

Page 76

Advertising
background image

68 | Accessories for Control Panels and Keypads | Expansion Modules

DX2010 Series Input

Expander

Features

▶ Up to eight sensor input loops
▶ Directly connects to the control panel data bus

The DX2010 Input Expander connects directly to the data
bus of a compatible control panel. Each expander adds
eight input loops. Install up to five expanders in a control
panel's enclosure (three on the interior sidewalls and two
on the back wall of the enclosure).

Certifications and Approvals

Region

Certification

Europe

CE

DX2010: 1999/5/EC, 2006/95/EC,
2004/108/EC; EN 55022:2006 +
A1:2007, Class B; EN 50130-4 w/
A1:1998 + A2:2003;
EN61000-3-2:2006;
EN61000-3-3:1995; EN 60950-1:2001;
TBR21:1998

Belgium

INCERT

DX2010 and DX2012 only

USA

UL

DX2010: AMCX: Central Station Alarm
Units (UL1610, UL1635), AMTB: Control
Panels, SIA False Alarm Reduction, AOTX:
Local Alarm Units (UL464, UL609), APAW:
Police Station Alarm Units (UL365,
UL464), APOU: Proprietary Alarm Units
(UL1076), NBSX: Household Burglar
Alarm System Units (UL1023), UTOU:
Control Units and Accessories - Household
System Type (UL985)

CSFM

DX2010: 7167-1615: 183 and
7167-1615: 223 July 2008

France

AFNOR

NF, A2P Type 2 (122000076-03)

Installation/Configuration Notes

Compatibility Information

Control Panels

Easy Series (ICP‑EZM2‑NA, ICP‑EZM2‑UK,

ICP‑EZM2‑LC), D4412, D6412, DS7220V2, and

DS7240V2

Technical Specifications

Outputs

Outputs:

100 mA, 12 VDC supervised output for acces-

sories

Environmental Considerations

Operating Temperature:

0°C to +50°C (+32°F to +122°F)

Relative Humidity:

5% to 85% at +30°C (+86°F), non‑condensing

Loop

Inputs:

Up to eight inputs

Input contacts may be normally‑open (NO) or

normally‑closed (NC) with appropriate end-of-

line resistor(s) for supervision.

Resistance:

60Ω maximum

Terminal Wire Size:

1.8 mm (14 AWG) to 0.8 mm (22 AWG)

Power Requirements

Current (Maximum):

35 mA standby

35 mA maximum with connected accessories

Voltage (Operating):

8 VDC to 14 VDC

Ordering Information

DX2010 Input Expander

Provides hard-wired expansion for an addi-

tional eight input points. Includes the DX2010

board.

DX2010

DX2011 Package

Includes a DX2010 Input Expander with a

D203 Metal Enclosure.

DX2011

DX2012 Package

Includes a DX2010 Input Expander with an

AE20 Plastic Enclosure.

DX2012

Accessories

AE20 Universal Plastic Enclosure

Mounts to a single gang/double gang box, a

9 cm (3.5 in.) octagonal box, or a 10 cm (4 in.)

square box. The dimensions are 12 cm x 16 cm

x 4 cm (4.7 in. x 6.2 in. x 1.5 in.). Accommo-

dates wall tamper switches on the modules.

AE20

D203 Enclosure

D203

Bosch Security Systems B.V.

www.boschsecurity.com

2