9function library l_iodrvethercat.lib – Lenze EtherCAT Controller-based Automation User Manual

Page 136

Advertising
background image

9

Function library L_IODrvEtherCAT.lib

9.2

CoE Interface

136

Lenze · Controller-based Automation · EtherCAT® Communication Manual · DMS 6.4 EN · 04/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Inputs (VAR_INPUT)

Outputs (VAR_OUTPUT)

Identifier/data type

Meaning/possible settings

xExecute

BOOL

A positive edge (TRUE) triggers a write request (downloading) of a CoE object.

xAbort

BOOL

A positive edge (TRUE) aborts a running write request (download).

xAbort is currently not supported in the Lenze control technology R3.x.

usiCom

USINT

EtherCAT master instance number

• In the Lenze control technology R3.x, only instance number 1 is currently

supported. usiCom has been pre-assigned with 1, so that the input can be left

open.

• A value that does not equal 1 causes the error ETC_E_INVALIDPARM

(0x9811000B).

uiDevice

UINT

EtherCAT address of the master/slave.

• The address 0 directly accesses the object directory of the EtherCAT master.

dwFlags

DWORD

dwFlags controls the function block behaviour:

• 16#00000000: Function block behaviour

L_ETC_CoE_SdoWrite (FB) ( 131)

• 16#00000001: "Complete access"

Type definition see

L_ETC_COE_FLAGS ( 155)

.

wIndex

WORD

CANopen index to be read in the object directory of the master or slave.

• Formula for converting a Lenze code number into a CANopen index: Index =

0x5FFF - code number

bySubindex

BYTE

Subindex in the object directory of the master or slave.

udiTimeout

UDINT

Timeout in milliseconds (ms)

• The value 0 is not permissible and causes the error ETC_E_INVALIDPARM

(0x9811000B).

pBuffer

CAA_PVOID

Reference to the memory buffer from which the values to be written are to be taken.

szSize

CAA_SIZE

Number of the bytes to be written

Identifier/data type

Meaning/possible settings

xDone

BOOL

• TRUE: An action has been executed successfully.

• FALSE: No action active / action is still being executed.

xBusy

BOOL

• TRUE: An action is currently being executed.

• FALSE: No action active

xError

BOOL

• TRUE: An error has occurred.

• FALSE: No error

eErrorCode

L_ETC_ERRORCODE

Error code of the incorrectly executed action (xError = TRUE).

General error codes (L_ETC_ERRORCODE) ( 183)

SDO abort codes ( 195)

udiSdoAbort

UDINT

If a write request (download) to the slave or master is rejected with an error, here the

CANopen abort code is returned.