Lenze · Controller-based Automation · EtherCAT® Communication Manual · DMS 6.4 EN · 04/2014 · TD17

51

7

Commissioning of the system

7.3

Detailed description of the commissioning steps

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.3.4.3

Exchanging i700 parameter sets between »PLC Designer« and »EASY Starter«

[7-4]

Parameter set transfer between »PLC Designer« and »EASY Starter«

The GDC files that have been stored on the Engineering PC with the help of »EASY Starter« can be

imported in »PLC Designer«.
It is also possible to export GDC files with »PLC Designer«; they can then be imported in »EASY

Starter«.
In the framework of this import/export functionality, the parameter settings of a single axis can be

imported into a double axis, for example.

How to import parameters in »PLC Designer«

1. Log out of the Lenze Controller with the menu command Online Logout or <Ctrl>+<F8>.
2. Select the corresponding Servo-Inverter i700 in the project tree.
3. Select and import the corresponding GDC file with the menu command Project Device

parameters Import device parameters.

4. Use the menu command Online Login or <Alt>+<F8> to log in on the Lenze Controller.

• For this, the PLC program must be error-free.
• The complete parameter set is written into the controller. The latter than transfers the

parameter set to the i700 servo inverter.

Parameters are exported in »PLC Designer« in a similar way with the help of the menu command

Project Device parameters Export device parameters.