Commissioning of the system

7.3

Detailed description of the commissioning steps

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.3.4.2

i700 parameter management in »EASY Starter«

For parameter management in »EASY Starter«, you must insert the Lenze Controller and the Servo-
Inverter i700 into the device list with the help of the

button.

[7-3]

Parameter set transfer with »EASY Starter«

With »EASY Starter«, there are two application cases for parameter management:

A. Storing the current Servo-Inverter i700 parameter setting in the Lenze Controller with mains

failure protection:

• Select the Lenze Controller from the device list.
• With the

button or the <F6> function key, store the parameter set in the controller so that

it is saved there even in the event of a power failure. (To this end, the controller uploads all

the parameter sets of the lower-level i700 servo inverter.)

• After the system has been switched off and then switched on again. the controller transfers

the parameter sets to the i700 inverter again.