5 l_etc_reseterrcnt (fb), L_etc_reseterrcnt (fb), L_etc_reseterrcnt (fb) ( 146) – Lenze EtherCAT Controller-based Automation User Manual

Page 146: 9function library l_iodrvethercat.lib

Advertising
background image

9

Function library L_IODrvEtherCAT.lib

9.4

Diagnostic Interface

146

Lenze · Controller-based Automation · EtherCAT® Communication Manual · DMS 6.4 EN · 04/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.4.5

L_ETC_ResetErrCnt (FB)

This function block resets the frame error counters of all connected slaves.
Visualisation: VISU_L_ETC_ResetErrCnt

Inputs (VAR_INPUT)

Outputs (VAR_OUTPUT)

Note!

We recommend executing the L_ETC_ResetErrCnt function block before one of the

frame error counters of the slaves has reached the maximum value of '255'.

L_ETC_ResetErrCnt

BOOL  xExecute

xDone  BOOL

xBusy  BOOL

xError  BOOL

eErrorCode  L_ETC_ERRORCODE

Identifier/data type

Meaning/possible settings

xExecute

BOOL

A positive edge (TRUE) resets the frame error counters of all connected slaves.

Identifier/data type

Meaning/possible settings

xDone

BOOL

• TRUE: An action has been executed successfully.

• FALSE: No action active / action is still being executed.

xBusy

BOOL

• TRUE: An action is currently being executed.

• FALSE: No action active

xError

BOOL

• TRUE: An error has occurred.

• FALSE: No error

eErrorCode

L_ETC_ERRORCODE

Error code of the incorrectly executed action (xError = TRUE).

General error codes (L_ETC_ERRORCODE) ( 183)

SDO abort codes ( 195)