7commissioning of the system – Lenze EtherCAT Controller-based Automation User Manual

Page 55

Advertising
background image

Lenze · Controller-based Automation · EtherCAT® Communication Manual · DMS 6.4 EN · 04/2014 · TD17

55

7

Commissioning of the system

7.3

Detailed description of the commissioning steps

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

2.

Select Control method (0x2C00 / 0x3400):

• Servo control for synchronous motor (SM)
• Servo control for asynchronous motor (ASM)
• VFC: V/f characteristic control

3. If you do not obtain the motor data from the catalog, you have to set the

moment of

inertia (0x2910/1 / 0x3110/1) to a non-zero value.
The controller parameters are calculated automatically.

4. You can select the parameters for the monitoring functions in the Monitoring settings

section.