2−92

l

EDSVF9383V−EXT EN 2.0

2.4.27.1

On−delay

l

C0720 = 0 (DIGDEL1)

l

C0725 = 0 (DIGDEL2)

t

t

DIGDEL1−IN

DIGDEL1−OUT

C0721

C0721

Fig. 2−72

On−delay (DIGDEL1)

In this function, the time−element operates like a retriggerable monoflop:

Function procedure

1. A LOW−HIGH edge at DIGDELx−IN starts the time element.

2. After the delay set under C0721 (DIGDEL1) or C0726 (DIGDEL2) has elapsed, DIGDELx−OUT

changes to HIGH.

3. A HIGH−LOW signal at DIGDELx−IN resets the time element and changes DIGDELx−OUT to

LOW.

2.4.27.2

Off−delay

l

C0720 = 1 (DIGDEL1)

l

C0725 = 1 (DIGDEL2)

t

t

DIGDEL1−IN

DIGDEL1−OUT

C0721

C0721

C0721

Fig. 2−73

Off−delay (DIGDEL1)

Function procedure

1. A LOW−HIGH signal at DIGDELx−IN changes DIGDELx−OUT to HIGH and resets the time

element.

2. A HIGH−LOW signal at DIGDELx−IN starts the time element.

3. After the delay set under C0721 (DIGDEL1) or C0726 (DIGDEL2) has elapsed, DIGDELx−OUT

changes to LOW.