Appendix, Index – Lenze EVF9383 User Manual

Page 231

Advertising
background image

Appendix

Index

5−5

l

EDSVF9383V−EXT EN 2.0

Blocking frequencies (NLIM), 2−132

building up a connection, 2−37

Change−over (ASW), 2−61

Characteristic function (CURVE), 2−77

Code assignment (FEVAN), 2−101

Comparison (CMP), 2−69

configuration code, 2−34

connecting, 2−35

Conversion (CONV), 2−74

Conversion phase to analog (CONVPHA), 2−76

Counter (FCNT), 2−97

Curve follower (FOLL), 2−108

CW/CCW/Quick stop (R/L/Q), 2−153

dead band (DB), 2−80

Delay (DIGDEL), 2−91

Delay (PT1), 2−150

designation, 2−33

Device control (DCTRL), 2−82

Change ofparameter set (PAR), 2−85
Controllerinhibit (CINH), 2−84
Operation inhibited(DISABLE), 2−84
Quick stop (QSP), 2−83
TRIP−RESET, 2−85
TRIP−SET, 2−84

diameter calculator (DCALC), 2−81

differentiation (DT1−1), 2−96

Digital frequency input (DFIN), 2−87

Digital frequency output (DFOUT), 2−88

Digital frequency processing (DFSET), 2−90

Digital frequency ramp function generator (DFRFG), 2−89

Digital inputs (DIGIN), 2−94

Digital outputs (DIGOUT), 2−95

Digital status signals (STAT), 2−159

display code, 2−34

Edge evaluation (TRANS), 2−160

Flipflop (FLIP), 2−106

Freedigital outputs (FDO), 2−99

Holding brake (BRK), Set pulse inhibit, 2−66

Holdingbrake (BRK), 2−63

Close brake, 2−64
Disengaging the brake, 2−65

input name, 2−33

input symbol, 2−33

integrator (INT), 2−110

− Internal motor control

Vector control (MCTRL2), 2−114
with V/f characteristic control (MCTRL1), 2−113

Inversion (ANEG), 2−56

Limitation (LIM), 2−112

Logic AND (AND), 2−53

Logic NOT (NOT), 2−133

Logic OR , 2−141

mains failure control (MFAIL), 2−115

Monitor outputs of monitoring system (MONIT), 2−128

motor phase failure detection (MLP), 2−127

Motor potentiometer (MPOT), 2−129

Oscilloscope function (OSZ), 2−144

output name, 2−34

output symbol, 2−34

parameterisation code, 2−34

Process controller (PCTRL), Controller for pressure, level, dancer position,

2−145

Programming of fixed setpoints (FIXSET), 2−104

Ramp function generator (RFG), 2−151

removing a connection, 2−38

S−ramp function generator (SRFG), 2−156

Sample & Hold (S&H), 2−154

signal types, 2−32

speed preconditioning (NSET), 2−135

Square−root calculator (SQRT), 2−155

system bus (CAN−IN), 2−68

system bus (CAN−OUT), 2−68

G

Global Drive Control, configuration by means of, 2−3

H

Holdingbrake (BRK), 2−63

I

Integrator (INT), 2−110

Internal motor control

V/f characteristic control (MCTRL1), 2−113

with vector control (MCTRL2), 2−114

Inversion (ANEG), 2−56

J

JOG setpoint, 2−7 , 2−15

JOG setpoints, 2−137

L

Limitation (LIM), 2−112

Logic NOT (NOT), 2−133

Logic OR , 2−141

M

Main setpoint channel, 2−137

Mains failure control, 2−118

Mains failure control (MFAIL), 2−115

fast mains recovery (KU), 2−126

mains failure control, 2−118

mains failure detection, 2−116

restart protection, 2−125