Application examples, Centre winder with internal diameter calculation – Lenze EVF9383 User Manual

Page 185

Advertising
background image

Application examples

Centre winder with internal diameter calculation

3−15

l

EDSVF9383V−EXT EN 2.0

The following values are required for parameter setting:

l

Rated line speed (V

LN

) selected via the digital frequency input X9.

l

Winding drive speed with rated line speed and minimum reel diameter (n

Dmin

).

– The winding drive speed results from the line speed V

L

and the reciprocal of the reel

diameter:

n

max

n ~

n

D

n

Dmax

n

Dmin

D

min

D

max

V
D

L

Fig. 3−10

Speed behaviour of the winding drive with reference to the reel diameter

d
D

max

D

min

Reel diameter
Maximum reel diameter
Minimum reel diameter

n
n

Dmax

n

Dmin

V

L

Winding drive speed
Winding drive speed with maximum reel diameter
Winding drive speed with minimum reel diameter
Line speed

Example

For a clearer representation of the parameter setting in this application example, the following values
are assumed for the calculations:

l

At rated line speed (V

LN

) the winding drive receives a digital frequency signal from which a

speed of 3000 rpm is calculated (DFIN−OUT).

l

The winding drive speed with minimum reel diameter and rated line speed V

LN

(n

DminN

) is

4000 rpm (MCTRL−PHI−ACT).

Advertising