Programming of fixed setpoints (FIXSET)

This FB is used to change an analog signal source to programmed fixed values.

You can use these fixed values e.g. for different dancer setpoint positions in a dancer position control
or different stretch ratios (gearbox factor) for a speed ratio synchronizing with digital frequency
coupling.

C0560/1

C0560/15

C0560/2

C0563

DMUX

0

3

0

15

FIXSET1−IN1*1

FIXSET1...15

C0564/1

FIXSET1−AIN

FIXSET1−IN2*2

C0564/2

FIXSET1−IN3*4

C0564/3

FIXSET1−IN4*8

C0564/4

FIXSET1−OUT

FIXSET1

C0561

C0562/1

C0562/2

C0562/3

C0562/4

Fig. 2−84

Programming of fixed setpoints (FIXSET1)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

FIXSET1−AIN

a

C0563

dec [%]

C0561

1

1000

The input is switched to the output, if a
LOW level is applied at all selection inputs
FIXSET−INx.

FIXSET1−IN1*1

d

C0564/1

bin

C0562/1

2

1000

The number of inputs to be assigned
depends on the number of required FIXSET
setpoints.

FIXSET1−IN2*2

d

C0564/2

bin

C0562/2

2

1000

FIXSET1−IN3*4

d

C0564/3

bin

C0562/3

2

1000

FIXSET1−IN4*8

d

C0564/4

bin

C0562/4

2

1000

FIXSET1−OUT

a

Function

The output of the FB can be used as a setpoint source (signal source) for another FB (e.g. process
controller, arithmetic block, etc.). The parameterization and handling is the same as for the JOG
setpoints in FB NSET. (

¶ 2−135)

l

Parameterization of the fixed setpoints

– The individual fixed setpoints are parameterized by the subcodes of C0560.

l

Output of the selected fixed setpoint:

– If the binary inputs are triggered with a HIGH signal, a fixed setpoint from the table is

switched to the output.

l

Range:

– The values for the fixed setpoint can be between −200 % and +200 %.

Advertising