Monitor outputs of monitoring system (monit), Configuration, 43 monitor outputs of monitoring system (monit) – Lenze EVF9383 User Manual

Page 136

Advertising
background image

Configuration

2−128

l

EDSVF9383V−EXT EN 2.0

2.4.43

Monitor outputs of monitoring system (MONIT)

Purpose

The monitoring functions output digital monitor signals.

FB_monit

LU

OU

EER

..

..

..

..

P18

SD8

nErr

MONIT

Fig. 2−100

Monitor outputs of the monitoring system (MONIT)

Function

The MONIT−outputs switch to HIGH level if one of the monitoring functions responds.

The digital monitor signals respond dynamically, i.e.

l

depending on the state of the monitoring function, but

l

independent of the selected fault reaction.

Example

MONIT−LP1 (motor phase monitoring) responds if a cable disruption is detected in a motor
connection phase, although the fault reaction of LP1 is set to "Off" (C0597 = 3).

Tip!

l

Only with a corresponding signal conditioning it is possible to use the MONIT−outputs to
detect the cause of malfunction afterwards (e.g. storing the signal by using function block
FLIP).

l

A detailed description concerning monitoring /fault messages can be found in the chapter
"Troubleshooting and fault elimination".