Speed control (c0005 = 1000), Configuration, Basic configuration – Lenze EVF9383 User Manual

Page 15

Advertising
background image

Configuration

Basic configuration

2−7

l

EDSVF9383V−EXT EN 2.0

2.2.3

Speed control (C0005 = 1000)

The configuration C0005 = 1000 (Lenze setting) has mainly been designed for single drives. The
setpoint speed for the drive is selected via the analog input X6/1. The signals are internally
conditioned together with the digital control signals.

Short setup

The "Short setup" menu contains the following codes. In the "Short setup" menu of the XT keypad
and "Global Drive Control", the codes are listed in the following order.

Code

Explanation

Lenze setting

C0005

Selection of the basic configuration

1000

C0010

Minimum speed

Reference value for the absolute and relative setpoint selection for the
acceleration and deceleration times

0 rpm

C0011

Maximum speed

3000 rpm

C0012

Acceleration time T

ir

of the main setpoint

5.00 s

C0013

Deceleration time T

if

of the main setpoint

5.00 s

C0034

Voltage / current range for analog signals at the input X6/1, X6/2

0

C0104

Selection of acceleration function of the linear ramp−function generator of NSET

0

C0038/1 ... C0038/6

Suppressing the speed ranges, function block NLIM1

0

C0039/1

JOG setpoints for the speed setpoint conditioning, function block NSET

1500 rpm

C0190

Arithmetic function, function block NSET
Connects main setpoint (C0046) and additional setpoint (C0040)

0

C0220

Acceleration time T

ir

for additional setpoint, function block NSET

2.00 s

C0221

Deceleration time T

if

for additional setpoint, function block NSET

2.00 s

C0105

Quick stop deceleration time

5.00 s

C0909

Speed limitation, function block MCTRL

1

C0026/1

Offset of AIN1 (X6/1, X6/2)

0.00 %

C0026/2

Offset of AIN2 (X6/3, X6/4)

0.00 %

C0027/1

Gain AIN1 (X6/1, X6/2)

100.00 %

C0027/2

Gain AIN2 (X6/3, X6/4)

100.00 %

C0006

Selection of the operating mode for the motor control

5

C0025

Speed feedback

1

C0019

Operating threshold − automatic DC injection brake (Auto−GSB)

0 rpm

C0036

Set continuous brake current

0.0 A

C0107

Hold time for automatic DC injection braking (Auto−GSB)

0.00 s

C0142

Start conditions for flying restart circuit

1

C0145

Selection of flying restart method

1

C0070

Speed controller gain

10.0

C0071

Adjustment time of speed controller

50 ms

C0074

Limitation of the speed controller

10.00 %

C0077

Adjustment time of field controller

4.0 ms

C0898

Torque limitation in the field weakening range, function block MCTRL

0

C0472/3

Free control code for analog signals

100.00%

C0017

Q

min

switching threshold

50 rpm

Advertising