Holding brake (brk), Configuration, 13 holding brake (brk) – Lenze EVF9383 User Manual

Page 71: Close brake, Open brake (release), Set controller inhibit

Advertising
background image

Configuration

2−63

l

EDSVF9383V−EXT EN 2.0

2.4.13

Holding brake (BRK)

This FB triggers a holding brake. You can use it e.g. in configurations for lift and travelling drives and
active loads.

C T R L

B R K 1 - S E T

C 0 4 5 9

B R K 1 - O U T

C 0 4 5 0

C 0 4 5 1

B R K 1 - N x

C 0 4 5 8 / 1

B R K 1 - Q S P

B R K 1 - M - S T O R E

B R K 1 - C I N H

B R K 1 - M - S E T

C 0 4 5 2

B R K 1 - S I G N

C 0 4 5 8 / 2

S I G N

t

0

t

0

D C T R L - I M P

M C T R L - N A C T

M C T R L - M A C T

C 0 1 9 5

C 0 1 9 6

C 0 2 4 4

B R K 1

M C T R L - N S E T 2

Fig. 2−45

Holding brake (BRK1)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

BRK1−SET

d

C0459

bin

C0451

2

1000

BRK1−NX

a

C0458/1

dec [%]

C0450

1

1000

Speed threshold from which the drive can
output the signal "close brake". The signal
source for this input can be a control code,
a fixed value or any other analog output of
a FB.

BRK1−SIGN

a

C0458/2

dec [%]

C0452

1

1000

Direction of the torque with which the drive
has to build a torque against the brake.The
signal source for this input can be a control
code, a fixed value or any other analog
output of a FB.

BRK1−M−SET

a

dec [%]

C0244

0.00

Holding torque of the DC injection brake
100 % = value of C0057

BRK1−T−ACT

a

dec

C0195

99.9

Brake engaging time

BRK1−T−RELEASE

a

dec

C0196

0.0

Brake disengaging time

Tip!

The function block processes the absolute values of the signals MCTRL−NACT, MCTRL−MACT,
MCTRL−NSET2 and BRK1−Nx.

Range of functions

l

Close brake

l

Open brake (release)

l

Set controller inhibit

Advertising