2.4.16.1
Function 1: CMP1−IN1 = CMP1−IN2
l
Selection: C0680 = 1
l
This function compares two signals. For instance, you can compare the actual speed and the
setpoint speed (n
act.
= n
set
).
l
The exact function can be obtained from the line diagram.
C0682
C0682
1
0
CMP1−IN2
CMP1−IN1
C0681
C0681
CMP1−IN2
C0681
C0682
C0681
C0682
CMP1−IN1
CMP1−OUT
t
t
Fig. 2−54
Equality of signals (CMP1−IN1 = CMP1−IN2)
Function procedure
1. Under C0682, set the window where the equality is to be effective.
2. Under C0681 you set a hysteresis if the input signals are not stable and therefore the output
oscillates.