Configuration – Lenze EVF9383 User Manual

Page 79

Advertising
background image

Configuration

2−71

l

EDSVF9383V−EXT EN 2.0

2.4.16.1

Function 1: CMP1−IN1 = CMP1−IN2

l

Selection: C0680 = 1

l

This function compares two signals. For instance, you can compare the actual speed and the
setpoint speed (n

act.

= n

set

).

l

The exact function can be obtained from the line diagram.

C0682

C0682

1

0

CMP1−IN2

CMP1−IN1

C0681

C0681

CMP1−IN2

C0681
C0682

C0681

C0682

CMP1−IN1

CMP1−OUT

t

t

Fig. 2−54

Equality of signals (CMP1−IN1 = CMP1−IN2)

Function procedure

1. Under C0682, set the window where the equality is to be effective.

2. Under C0681 you set a hysteresis if the input signals are not stable and therefore the output

oscillates.