Centre winder with internal diameter calculation, Application examples, 7 centre winder with internal diameter calculation – Lenze EVF9383 User Manual

Page 184

Advertising
background image

Application examples

Centre winder with internal diameter calculation

3−14

l

EDSVF9383V−EXT EN 2.0

3.7

Centre winder with internal diameter calculation

This application is based on the basic configuration C0005 = 9000.

M

M

Q

R

S

T

U

W

X

V

Y

Fig. 3−9

Basic structure of a dancer position control with internal diameter detection



‚

ƒ

„

…

Line speed
Dancer
Winder
Material guide for CW rotation of the winder
Material guide for CCW rotation of the winder

†

‡

ˆ

‰

Preset diameter
Actual dancer position
Digital frequency proportional to the line speed
Initial diameter

Input and output assignment

Winding drive

Digital frequency input

X9

·

Line speed

Analog input

X6/1,2

·

Actual dancer position

X6/3,4

·

Initial diameter

Digital inputs

X5/28

·

Controller enable

X5/E1, X5/E2

·

Direction of rotation/quick stop

X5/E3

·

Loading the actual value

X5/E4

·

Accepting the initial diameter

X5/E5

·

TRIP reset

Digital outputs

X5/A1

·

Error (TRIP)

X5/A2

·

Actual dancer position = setpoint

X5/A3

·

Ready for operation (RDY)

X5/A4

·

D

min

/D

max

reached

Analog outputs

X6/62

·

Actual speed

X6/63

·

Motor current

Advertising