Configuration, Basic configuration – Lenze EVF9383 User Manual

Page 19

Advertising
background image

Configuration

Basic configuration

2−11

l

EDSVF9383V−EXT EN 2.0

M

M

0

1

9300VEC010

Fig. 2−3

Basic structure of a step controller for a bulk material filling station

0

Dosing drive

1

Conveyor drive

Input and output assignment

Dosing drive

Conveyor drive

Analog inputs

·

Dosing speed

·

Dosing amount

·

Conveyor speed

·

Step width

Digital inputs

·

Controller enable

·

Direction of rotation

·

Defined dosing amount

·

Start dosing

·

TRIP reset

·

Controller enable

·

Step direction

·

Defined step width

·

Start step

·

TRIP reset

Digital outputs

·

Error (TRIP)

·

Current speed

> C0017 (Qmin)

·

Ready for operation (RDY)

·

Dosing completed

·

Error (TRIP)

·

Current speed

> C0017 (Qmin)

·

Ready for operation (RDY)

·

Step completed

Analog outputs

·

Actual speed

·

Motor current

·

Actual speed

·

Motor current

Advertising