Connecting function blocks, Configuration, Use of funktion blocks – Lenze EVF9383 User Manual

Page 43: 3 connecting function blocks, Stop

Advertising
background image

Configuration

Use of funktion blocks

2−35

l

EDSVF9383V−EXT EN 2.0

2.3.3

Connecting function blocks

General rules

l

To every input a signal source is assigned.

l

Every input can only have one signal source.

l

Inputs of different function blocks can have the same signal source.

l

Only identical signal types can be combined.

(

Stop!

Existing connections that are not wanted must be reconfigured and removed.
Otherwise, the drive may execute functions that are not desired.

)

Note!

Lenze provides a network list generator for the visualisation of existing connections.

AND1

&

AND1−IN1

AND1−IN2

AND1−IN3

AND1−OUT

C0821/1

C0821/2

C0821/3

C0820/1

C0820/2

C0820/3

OR1

|1

OR1−IN1

OR1−IN2

OR1−IN3

OR1−OUT

C0831/1

C0831/2

C0831/3

C0830/1

C0830/2

C0830/3

NOT1

1

NOT1−OUT

NOT1−IN

C0841

NOT2

1

NOT2−OUT

NOT2−IN

C0843

C0840

C0842

t

0

DIGDEL1−IN

C0724

DIGDEL1−OUT

DIGDEL1

C0721

C0720

C0723

Connection not possible

Connection possible

x

Fig. 2−16

Correct connection of function blocks

Advertising