Configuration

2−154

l

EDSVF9383V−EXT EN 2.0

2.4.54

Sample & Hold (S&H)

This FB can accept analog signals and save them non−volatile. The saved value is also available after
mains disconnection.

C0572

S&H1

S&H1−OUT

S&H1−IN

C0573

S&H1−LOAD

C0570

C0571

S&H

Fig. 2−132

Sample & Hold (S&H1)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

S&H1−IN

a

C0572

dec [%]

C0570

1

1000

S&H1−LOAD

d

C0573

bin

C0571

2

1000

LOW = save

S&H1−OUT

a

Function

l

With S&H1−LOAD = HIGH the signal at the input S&H1−IN is switched to the output
S&H1−OUT.

l

With S&H1−LOAD = LOW the output S&H1−OUT is disconnected from the input S&H1−IN and
outputs the value which was last valid and S&H−OUT outputs the value which was accepted
last.

l

Saving before mains disconnection:

– The value which was accepted last is saved non−volatile in the internal memory before the

supply voltage is switched off. When the supply voltage is switched on, the saved value is
loaded into the FB S&H1.