Comparing counter

l

C1100 = 1

– If | counter content |

³ | FCNT1−CMP−VAL | (comparison value), FCNT1−EQUAL is set = HIGH

for 1 ms. Afterwards the counter is reset to the starting value (FCNT1−LD−VAL).

)

Note!

If the signal is to be available longer, e. g. for a query of the output via a PLC, you
can prolong the signal via the TRANS function block.

l

C1100 = 2

– If | counter content |

³ | FCNT1−CMP−VAL | (comparison value), the counter is stopped.

– Via FCNT1−LOAD = HIGH, the counter is reset to the starting value (FCNT1−LD−VAL).

l

C1100 = 3

– If | counter content| = | FCNT1−CMP−VAL | (comparison value), the counter is stopped.

– Via FCNT1−LOAD = HIGH, the counter is reset to the starting value (FCNT1−LD−VAL).