Configuration, Range of functions, Quick stop (qsp) – Lenze EVF9383 User Manual

Page 91: Operation inhibited (disable), Controller inhibit (cinh), Trip−set, Trip−reset, Changing the parameter set (par), All inputs are linked by an or−operation

Advertising
background image

Configuration

2−83

l

EDSVF9383V−EXT EN 2.0

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

DCTRL−CINH1

d

C0878/1

bin

C0870/1

2

1000

HIGH = inhibit controller

DCTRL−CINH2

d

C0878/2

bin

C0870/2

2

1000

HIGH = inhibit controller

DCTRL−TRIP−SET

d

C0878/3

bin

C0871

2

54

HIGH = fault indication EEr

DCTRL−TRIPRESET

d

C0878/4

bin

C0876

2

55

LOW−HIGH signal = Trip reset

DCTRL−PAR*1

d

C0884/1

bin

C0880/1

2

1000

Select parameter set

DCTRL−PAR*2

d

C0884/2

bin

C0880/2

2

1000

Select parameter set

DCTRL−PAR−LOAD

d

C0884/3

bin

C0881

2

1000

LOW−HIGH signal = Load parameter set

DCTRL−RDY

d

HIGH = Ready for operation

DCTRL−CINH

d

HIGH = Controller reset

DCTRL−IMP

d

HIGH = High−resistance power output
stages

DCTRL−TRIP

d

HIGH = Active fault

DCTRL−WARN

d

HIGH = Active warning

DCTRL−MESS

d

HIGH = Active message

DCTRL−FAIL

d

DCTRL−CW/CCW

d

LOW = CW rotation, HIGH = CCW rotation

DCTRL−NACT=0

d

HIGH = Motor speed < C0019

DCTRL−STAT*1

d

general status (binary coded)

DCTRL−STAT*2

d

general status (binary coded)

DCTRL−STAT*4

d

general status (binary coded)

DCTRL−STAT*8

d

general status (binary coded)

DCTRL−INIT

d

DCTRL−PARBUSY

d

HIGH = Change of parameter set active

DCTRL−PAR*1−O

d

Parameter set X active (binary coded)

DCTRL−PAR*2−0

d

Parameter set X active (binary coded)

Range of functions

l

Quick stop (QSP)

l

Operation inhibited (DISABLE)

l

Controller inhibit (CINH)

l

TRIP−SET

l

TRIP−RESET

l

Changing the parameter set (PAR)

l

Controller state

2.4.22.1

Quick stop (QSP)

If QSP is activated, the drive is decelerated to zero speed via the deceleration ramp C0105.

l

QSP is activated via three inputs:

– Control word CAN−CTRL.B3 from CAN−IN1

– Control word AIF−CTRL.B 3 from AIF−IN

– Control word C0135.B3

l

All inputs are linked by an OR−operation

l

QSP can also be activated via the input MCTRL−QSP in the FB MCTRL.