Traversing drive for a wire winder, Application examples, 5 traversing drive for a wire winder – Lenze EVF9383 User Manual

Page 178: Traversing for a wire winder

Advertising
background image

Application examples

Traversing for a wire winder

3−8

l

EDSVF9383V−EXT EN 2.0

3.5

Traversing drive for a wire winder

This application is based on the basic configuration C0005 = 3000.

R

Q

S

T

U

V

Fig. 3−5

Basic structure of a traversing controller



Winding drive

‚

Traversing drive

ƒ

Reference setpoint (winding drive)

„

Traversing unit

…

Limit switch for changeover to CCW rotation

†

Limit switch for changeover to CW rotation

Input and output assignment

Traversing drive

Analog input

X6/1,s

·

Reference setpoint

Digital inputs

X5/28

·

Controller enable

X5/E1, X5/E2

·

Direction of rotation/quick stop

X5/E3

·

Additional setpoint

X5/E4

·

Start traversing

X5/E5

·

TRIP reset

Digital outputs

X5/A1

·

Error (TRIP)

X5/A2

·

Current speed > C0017 (Q

min

)

X5/A3

·

Ready for operation (RDY)

X5/A4

·

Traversing break

Analog outputs

X6/62

·

Actual speed

X6/63

·

Motor current

Advertising