Configuration

2−139

l

EDSVF9383V−EXT EN 2.0

Priorities:

CINH

NSET−LOAD

NSET−RFG−0

NSET−RFG−STOP

Function

0

0

0

0

RFG follows the input value via the set ramps

0

0

0

1

The value at the output of RFG is frozen

0

0

1

0

RFG decelerates to zero along the set deceleration ramp

0

0

1

1

0

1

0

0

RFG accepts the value at the input NSET−SET and provides it at its
output

0

1

0

1

0

1

1

0

0

1

1

1

1

0

0

0

RFG accepts the value at the input NSET−CINH−VAL and provides it at its
output

1

0

0

1

1

0

1

0

1

0

1

1

1

1

0

0

1

1

0

1

1

1

1

0

1

1

1

1

0 = LOW

1 = HIGH

2.4.47.5

Acceleration functions

Under C0104, you can select the following acceleration functions for the linear ramp function
generator:

Code

Function

Application

C0104 = 0

The drive starts and stops with constant acceleration.
The actual acceleration time is proportional to the selected
setpoint and the activated T

i

time. The following formula

applies:

t

acc

+ T

i

@

n

soll

n

max

C0104 = 1

The drive starts and stops in the activated T

i

time.

The selected setpoint has no influence on the acceleration
time. The following formula applies:

With acceleration with a fixed time, a drive system is, for
instance, simultaneously accelerated and decelerated to
standstill. The individual drives can have different speed values.

t

acc

+ T

i

C0104 = 2

The drive starts and stops with a predefined number of
revolutions or over a selected distance.
The actual acceleration time results from the selected setpoint
and the activated T

i

time. The following formula applies:

With acceleration over a specified distance, the distance
selected via the T

i

time is traversed when the drive is

decelerated to standstill. The speed does not have any
influence.

t

acc

+ T

i

@

n

max

n

soll

Start and stop with a preselected time or distance is only possible with the control signal at