Configuration – Lenze EVF9383 User Manual

Page 56

Advertising
background image

Configuration

2−48

l

EDSVF9383V−EXT EN 2.0

Function

The input signals of the 8 byte user data of the AIF object are converted into corresponding signal
types. The signals can be used via further function blocks.

Control word (Byte 1, 2)

Byte 1, 2 form the control word for the controller. The bits 3, 8, 9, 10, and 11 of these bytes are directly
transferred to the function block DCTRL where they are linked to other signals. The other 11 bits can
be used to control further function blocks.

Byte 3, 4

Byte 3, 4 are the signal to AIF−IN.W1.

Byte 5, 6, and byte 7, 8

The meaning of these user data results from the different signal types which you can select.
Depending on the requirement, these data can be evaluated as up to 2 analog signals, 32 digital
signals or one phase signal. Mixed forms are also possible.