Configuration, Transmission errors can occur, if, The target code is not available – Lenze EVF9383 User Manual

Page 110: The target subcode is not available

Advertising
background image

Configuration

2−102

l

EDSVF9383V−EXT EN 2.0

2.4.33.1

Data transmission

The data transmission is started with a LOW−HIGH signal at FEVAN1−LOAD. FEVAN1−BUSY = HIGH
is set for the time of transmission.

Correct transmission

Wrong transmission

FEVANx-FAIL

FEVANx-BUSY

FEVANx-LOAD

9300kur089

Fig. 2−82

Signal flow

Transmission errors can occur, if:

l

the target code is not available

l

the target subcode is not available

l

the transmitted data are out of the target code limits

l

the target code is inhibited since it can only be written if the controller is inhibited. Inhibit the
controller (see code table).

Cyclic data transmission

F E V A N 1 - I N

C 1 0 9 8

C 1 0 9 6

C 1 0 9 3
C 1 0 9 4

C T R L

+

+

C 1 0 9 5

S & H

C 1 0 9 9

F E V A N 1 - L O A D

C 1 0 9 7

C 1 0 9 0

C o d e / S u b c o d e

( C x x x x / y y y )

C 1 0 9 2

C 1 0 9 1

F E V A N 1 - B U S Y

F E V A N 1 - F A I L

F E V A N 1

N O T 1

1

N O T 1 - O U T

N O T 1 - I N

C 0 8 4 1

C 0 8 4 0

Q

Fig. 2−83

Example for a cycle data transmission to a target code
 Input signal which is to be transmitted to the target code