Configuration – Lenze EVF9383 User Manual
Page 169
Configuration
2−161
l
EDSVF9383V−EXT EN 2.0
2.4.58.1
Evaluate positive edge
l
C0710 = 0 (TRANS1)
l
C0715 = 0 (TRANS2)
t
t
TRANS1−IN
TRANS1−OUT
C0711
C0711
Fig. 2−141
Evaluation of positive edges (TRANS1)
Function procedure
1. With a LOW−HIGH edge at TRANSx−IN, TRANSx−OUT = HIGH.
2. After the time set under C0711 (TRANS1) or C0716 (TRANS2) has elapsed, TRANSx−OUT
switches to LOW again.
– Every new trigger event (LOW−HIGH edge at TRANSx−IN) switches TRANSx−OUT = HIGH
and restarts the elapsing time.
2.4.58.2
Evalute negative edge
l
C0710 = 1 (TRANS1)
l
C0715 = 1 (TRANS2)
t
t
TRANS1−IN
TRANS1−OUT
C0711
C0711
Fig. 2−142
Evaluation of negative edges (TRANS1)
Function procedure
1. With a HIGH−LOW edge at TRANSx−IN, TRANSx−OUT = HIGH.
2. After the time set under C0711 (TRANS1) or C0716 (TRANS2) has elapsed, TRANSx−OUT
switches to LOW again.
– Every new trigger event (LOW−HIGH edge at TRANSx−IN) switches TRANSx−OUT = HIGH
and restarts the elapsing time.