Configuration – Lenze EVF9383 User Manual

Page 169

Advertising
background image

Configuration

2−161

l

EDSVF9383V−EXT EN 2.0

2.4.58.1

Evaluate positive edge

l

C0710 = 0 (TRANS1)

l

C0715 = 0 (TRANS2)

t

t

TRANS1−IN

TRANS1−OUT

C0711

C0711

Fig. 2−141

Evaluation of positive edges (TRANS1)

Function procedure

1. With a LOW−HIGH edge at TRANSx−IN, TRANSx−OUT = HIGH.

2. After the time set under C0711 (TRANS1) or C0716 (TRANS2) has elapsed, TRANSx−OUT

switches to LOW again.

– Every new trigger event (LOW−HIGH edge at TRANSx−IN) switches TRANSx−OUT = HIGH

and restarts the elapsing time.

2.4.58.2

Evalute negative edge

l

C0710 = 1 (TRANS1)

l

C0715 = 1 (TRANS2)

t

t

TRANS1−IN

TRANS1−OUT

C0711

C0711

Fig. 2−142

Evaluation of negative edges (TRANS1)

Function procedure

1. With a HIGH−LOW edge at TRANSx−IN, TRANSx−OUT = HIGH.

2. After the time set under C0711 (TRANS1) or C0716 (TRANS2) has elapsed, TRANSx−OUT

switches to LOW again.

– Every new trigger event (LOW−HIGH edge at TRANSx−IN) switches TRANSx−OUT = HIGH

and restarts the elapsing time.

Advertising