Traversing control (c0005 = 3000), Configuration, Basic configuration – Lenze EVF9383 User Manual

Page 20

Advertising
background image

Configuration

Basic configuration

2−12

l

EDSVF9383V−EXT EN 2.0

2.2.5

Traversing control (C0005 = 3000)

The configuration C0005 = 3000 is designed for spindle drives moving material by means of winding.

The speed of the winding drive is transferred via the analog input X6/1 which is used to control the
speed of the traversing drive. The reversing of the direction of rotation is controlled via the digital
inputs X5/E1 and X5/E2. Limit switches operating as normally closed contacts which disable the
active direction of rotation can for example be used for this purpose.

Short setup

The "Short setup" menu contains the following codes. In the "Short setup" menu of the XT keypad
and "Global Drive Control", the codes are listed in the following order.

Code

Explanation

Lenze setting

C0005

Selection of the basic configuration

3000

C0011

Maximum speed

Reference value for the absolute and relative setpoint selection for the
acceleration and deceleration times

3000 rpm

C0012

Acceleration time T

ir

of the main setpoint

1.00 s

C0013

Deceleration time T

if

of the main setpoint

1.00 s

C0034

Voltage / current range for analog signals at the input X6/1, X6/2

0

C0104

Selection of acceleration function of the linear ramp−function generator of NSET

2

C0141

Additional setpoint for inching, activated via input X5/E3

10.00 %

C0472/1

Selection of traversing step

100.00 %

C0474/1

Selection of traversing break
(65536 results in a break of one motor revolution, if 100 % reference setpoint = 3000 rpm)

10000 inc

C0655

Numerator

Conversion factor, function block CONV5

C0655 = 1

C0656

Denominator

C0656 = 5

C0190

Arithmetic function, function block NSET
Connects main setpoint (C0046) and additional setpoint (C0040)

0

C0105

Quick stop deceleration time

5.00 s

C0026/1

Offset of AIN1 (X6/1, X6/2)

0.00 %

C0026/2

Offset of AIN2 (X6/3, X6/4)

0.00 %

C0027/1

Gain AIN1 (X6/1, X6/2)

100.00 %

C0027/2

Gain AIN2 (X6/3, X6/4)

100.00 %

C0685

Comparison function, function block CMP2

1

C0686

Hysteresis for input signals, function block CMP2

0.00 %

C0687

Window for signal comparison, function block CMP2

0.00 %