The input signals of this FB are copied to the 8 byte user data of the AIF object and laid on the
connected field bus module. The meaning of the user data can be determined very easily with C0852
and C0853 and the corresponding configuration codes.

Status word (Byte 1, 2)

Here, the status word of the function block STAT is mapped.Some of the bits are freely assignable.
(

2−159)

Byte 3, 4

The analog signal at AIF−OUT.W1 is output.

Byte 5, 6

l

C0852 = 0

– The analog signal to AIF−OUT.W2 is output.

l

C0852 = 1

– Bits 0 ... 15 of FDO are output.

l

C0852 = 2

– The LOW WORD from AIF−OUT.D1 is output.

Byte 7, 8

l

C0853 = 0

– The analog signal at AIF−OUT.W3 is output.

l

C0853 = 1

– Bits 16 ... 31 of FDO are output.

l

C0853 = 2

– The HIGH WORD of AIF−OUT.D1 is output.

Example

You want to output 16 digital signals of FDO and the LOW WORD of AIF−OUT.D1:

l

The LOW−WORD of AIF−OUT.D1 can only be output on byte 5 and 6.

– For this, C0852 is set to 2. The phase signal at C0851 is output on byte 5 and 6.

l

For the digital signals, only the bits 16 ... 31 (byte 7 and 8) are available:

– For this, C0853 is set to 1. Bit 16 ... 31 (FDO) are output on byte 7 and 8.