Configuration

2−73

l

EDSVF9383V−EXT EN 2.0

2.4.16.4

Function 4: |CMP1−IN1| = |CMP1−IN2|

l

Selection: C0680 = 4

l

This function is used to carry out the comparison "|n

act.

| = |n

x

|" for instance.

l

This function is the same as function 1. (

2−71)

– However, the absolute value of the input signals (without sign) is created before the signals

are processed.

2.4.16.5

Function 5: |CMP1−IN1| > |CMP1−IN2|

l

Selection: C0680 = 5

l

This function is used to carry out the comparison "|n

act.

| > |n

x

|" independently of the direction

of rotation.

l

This function is the same as function 3. (

2−72)

– However, the absolute value of the input signals (without sign) is created before the signals

are processed.

2.4.16.6

Function 6: |CMP1−IN1| < |CMP1−IN2|

l

Selection: C0680 = 6

l

This function is the same as function 2. (

2−72)

– However, the absolute value of the input signals (without sign) is created before the signals

are processed.

l

This function is used to carry out the comparison "|n

act.

| < |n

x

|" independently of the direction

of rotation.