Dead band (db), Configuration, 20 dead band (db) – Lenze EVF9383 User Manual

Page 88

Advertising
background image

Configuration

2−80

l

EDSVF9383V−EXT EN 2.0

2.4.20

Dead band (DB)

This FB eliminates input signals around the zero point (e.g. disturbances on analog input voltages).

DB1

DB1-OUT

DB1-IN

C0623

C0622

±199.99 %

C0621

C0620

Fig. 2−67

Dead band (DB1)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

DB1−IN

a

C0623

dec [%]

C0622

1

1000

DB1−OUT

a

limited to ±199.99 %

Function

C0621

C0620

DB1−in

DB1−OUT

Fig. 2−68

Dead band and gain

l

Under C0621 you can set the parameters for the dead band.

l

Under C0620 you can alter the gain.