Dosing drive for a filling station, Application examples, 4 dosing drive for a filling station – Lenze EVF9383 User Manual

Page 176

Advertising
background image

Application examples

Dosing drive for a filling station

3−6

l

EDSVF9383V−EXT EN 2.0

3.4

Dosing drive for a filling station

This application is based on the basic configuration C0005 = 2000.

Q

R

Fig. 3−4

Basic structure of a step controller for a bulk material filling station
 Dosing drive
‚ Conveyor drive

Input and output assignment

Dosing drive

Conveyor drive

Analog inputs

X6/1,2

·

Dosing speed

·

Conveyor speed

X6/3,4

·

Dosing amount

·

Step width

Digital inputs

X5/28

·

Controller enable

·

Controller enable

X5/E1, X5/E2

·

Direction of rotation/quick stop

·

Step direction/quick stop

X5/E3

·

Fixed dosing amount

·

Fixed step width

X5/E4

·

Start dosing

·

Start step

X5/E5

·

TRIP reset

·

TRIP reset

Digital outputs

X5/A1

·

Error (TRIP)

·

Error (TRIP)

X5/A2

·

Current speed

> C0017 (Qmin)

·

Current speed > C0017 (Q

min

)

X5/A3

·

Ready for operation (RDY)

·

Ready for operation (RDY)

X5/A4

·

Dosing completed

·

Step completed

Analog outputs

X6/62

·

Actual speed

·

Actual speed

X6/63

·

Motor current

·

Motor current

Tip!

If the required amount has not yet been reached at the end of dosing, you can control redosing via
the setpoint.

Advertising