2.4.41

Mains failure control (MFAIL)

This FB is used to decelerate the drive/drive network in a controlled manner to standstill. Without this
function, the drive/drive network would coast down after a mains failure.

Tip!

The basic configurations speed control with mains failure control (C0005 = 14xx) and digital
frequency master with mains failure control (C0005 = 54xx) are application examples which can be
directly loaded.

C 0 9 8 8 / 7

M F A I L - D C - S E T

C 0 9 8 9 / 1

M F A I L - F A U L T

M F A I L - R E S E T

C 0 9 8 2

C 0 9 7 1

C 0 9 7 2

C 0 9 7 8

M F A I L - A D A P T

C 9 8 8 / 2

C 0 9 7 3

C 0 9 7 4

C 0 9 8 1

+

-

1
0

C 0 9 8 8 / 1

C 0 9 7 0

M F A I L - C O N S T

C 9 8 8 / 3

C 0 9 8 0

V p

T n

M C R T L -

D C V O L T

C 0 9 8 9 / 2

M F A I L - T H R E S H O L D

C 0 9 7 5

C 0 9 8 8 / 4

M F A I L - N A C T

C 0 9 7 6

C 0 9 8 8 / 5

M F A I L - S E T

C 0 9 7 7

C 0 9 8 8 / 6

C T R L

M F A I L - I - R E S E T

M F A I L - N O U T

M F A I L - S T A T U S

M F A I L

+

-

M F A I L - N - S E T

C 0 9 8 3

Fig. 2−92

Mains failure control (MFAIL)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

MFAIL−N−SET

a

C0988/1

dec [%]

C0970

1

1000

Speed setpoint in [%] of C0011

MFAIL−ADAPT

a

C0988/2

dec [%]

C0973

1

1000

Dynamic adaptation of the proportional
gain of the U

Gset

controller in [%] of C0980

MFAIL−KONST

a

C0988/3

dec [%]

C0974

1

1000

Proportional gain of the U

Gset

controller in

[%] of C0980

MFAIL−THRESHOLD

a

C0988/4

dec [%]

C0975

1

1000

Restart threshold in [%] of C0011

MFAIL−NACT

a

C0988/5

dec [%]

C0976

1

1000

Comparison value for the restart threshold
in [%] of C0011

MFAIL−SET

a

C0988/6

dec [%]

C0977

1

1000

Speed starting point for deceleration in
[%] of C0011

MFAIL−DC−SET

a

C0988/7

dec [%]

C0978

1

1000

Voltage setpoint at which the DC−bus
voltage is to be maintained,
100 % = 1000 V

MFAIL−FAULT

d

C0989/1

bin

C0971

2

1000

HIGH = activates the mains failure control

MFAIL−RESET

d

C0989/2

bin

C0972

2

1000

HIGH = reset

MFAIL−N−OUT

a

Speed setpoint in [%] of C0011

MFAIL−STATUS

d

HIGH = mains failure control is active

MFAIL−I−RESET

d

HIGH = mains failure control is active, the
drive is braking