Configuration – Lenze EVF9383 User Manual

Page 60

Advertising
background image

Configuration

2−52

l

EDSVF9383V−EXT EN 2.0

Function

l

Offset

– The value at AINx−OFFSET is added to the value at AINx−IN.

– The result of the addition is limited to ±200%.

l

Gain

– The limited value (after offset) is multiplied with the value at AINx−GAIN.

– The signal is then limited to ±200 %.

l

The signal is output at AINx−OUT.

ОООО

ОООО

AIN−OFFSET

AIN−GAIN

IN

AIN−OUT

Fig. 2−27

Offset and gain of the analog input

Special feature of AIN1

l

A minimum speed can be set under C0010. The signal gain is reduced such that the signal at
AIN1−OUT = 100 % with a setpoint of 10 V at X6/1 and X6/2.

– Setting range: 0 ... 36000 rpm

– Setting range: 0 rpm (function inactive)

– Input limits: C0010 < C0011

– AIN1−OFFSET and AIN1−GAIN are independent of C0010.

l

A dead band element can be integrated into the output signal at AIN1 via C0034. You can
achieve the function 4 ... 20 mA as a current master value together with the jumper setting X2
(controller front).

l

The signal at X6/1 and X6/2 is read cyclically (1 ms).

Special feature of AIN2

l

The signal at X6/3 and X6/4 is read cyclically (250

ms).

Advertising
This manual is related to the following products: