Step 15, Figure 64 – Rockwell Automation 23P PowerFlex Digital DC Drive User Manual

Page 104

Advertising
background image

104

Rockwell Automation Publication 20P-UM001K-EN-P - July 2014

Chapter 2

Drive Start Up

Figure 64 - Motor Connections

13.

Apply power to the drive.

14.

Repeat

step 6

step 9 on page

103

. When the motor rotation direction

is correct, continue with

step 15

.

15.

Complete the appropriate procedure below based on the type of
feedback device used for the application:

❏ For armature voltage feedback - Continue with

step 16

below.

❏ For analog tachometer feedback - Assert a Jog command and verify

that the sign and value of Par 1408 [Tachometer Speed]
corresponds with the actual direction of the motor. If the sign and
value of Par 1408 [Tachometer Speed] and the motor direction do
not correspond, remove power from the drive and reverse the
tachometer connections at the drive. Verify proper motor rotation
and continue with

step 16

below.

❏ For encoder feedback - Assert a Jog command and verify that the

sign and value of Par 420 [Encoder Speed] correspond with the
actual direction of the motor. If the sign and value of [Par 420
[Encoder Speed] and the motor direction do not correspond,
remove power from the drive and reverse the encoder connections at
the drive. Reverse the polarity of only one channel, for example, B
and B NOT. See

Table 38

on page

86

for digital encoder terminal

block designations. Verify proper motor rotation and continue with

step 16

below.

❏ For resolver feedback - Assert a Jog command and verify that the

sign and value of Par 428 [Resolver Speed] correspond with the
actual direction of the motor. If the sign and value of Par 428
[Resolver Speed] and the motor direction do not correspond,
change the setting of bit 5 “Resolver Dir” in Par 425 [Resolver
Config], or remove power from the drive and verify the correct
resolver connections to the drive (refer to resolver installation
instructions for details). Verify proper motor rotation and continue
with

step 16

below.

C1 (+)

C (+)

D (-)

D1 (-)

PowerFlex DC

Motor

F1 (+)

A1

A2

F2 (-)

(2)

(2)

C1 (+)

C (+)

D (-)

D1 (-)

PowerFlex DC

Motor

F1 (+)

A1

A2

F2 (-)

(2)

(2)

Straight Shunt Machine,

CCW Rotation Facing Commutator End

Straight Shunt Machine,

CW Rotation Facing Commutator End