Rockwell Automation 23P PowerFlex Digital DC Drive User Manual

Page 150

Advertising
background image

150

Rockwell Automation Publication 20P-UM001K-EN-P - July 2014

Chapter 3

Programming and Parameters

SPEE

D C

O

MMAND

Sp

ee

d Regula

tor

435

[Act Spd Reg BW]
Displays the actual speed regulator bandwidth or crossover frequency. It
represents the bandwidth in Par 434 [Spd Reg BW] after the maximum
bandwidth limits have been applied.
Note: This parameter was added for firmware version 6.001.

Default:

Min/Max:
Units:

Read Only

0.0 / 100.0
rad / sec

Real

434

436

[Spd Reg Damping]
Sets the damping factor of the drive’s characteristic equation and factors in
the calculation of the integral gain set in Par 88 [Spd Reg Ki]. A factor of 1.0 is
considered critical damping. When Par 434 [Spd Reg BW] is set to zero, the
damping factor has no effect on drive operation.
Note: This parameter was added for firmware version 6.001.

Default:

Min/Max:

1.0

0.5 / 30.0

Real

444

[Spd Reg P Filter]
Time constant used by the filter for the Speed Feedback circuit. Filtering of
the high frequency components of the speed feedback signal is useful in the
case of elastic coupling between the motor and load (i.e., joints or belts).
Note: This parameter was renamed for firmware version 4.001.

Default:

Min/Max:
Units:

0

0 / 1000
ms

16-bit
Int

121,
122

445

[Spd Up Gain Pct]
The Speed Up function gain as a percentage of Par 446 [Speed Up Base].
Note: See Speed Up Function on page

320

for more information.

Default:

Min/Max:
Units:

0.00

0.00 / 100.00
%

Real

446

446

[Speed Up Base]
The Speed Up function maximum gain. This value corresponds to 100% of Par
445 [Spd Up Gain Pct].
Note: See Speed Up Function on page

320

for more information.

Default:

Min/Max:
Units:

1000.00

0.00 / 16000.00
ms

Real

445

447

[Speed Up Filter]
The time constant of the filter for the D (derivative) component of the Speed
Up function.
Note: See Speed Up Function on page

320

for more information.

Default:

Min/Max:
Units:

0

0 / 1000
ms

16-bit
Int

448

[SpdReg BW Bypass]
Sets the bandwidth of the speed regulator, when bypassed, in rad/sec.
Bandwidth is also referred to as the crossover frequency. Small signal time
response is approximately 1/BW and is the time to reach 63% of setpoint. A
change to this parameter will cause an automatic update of Pars
459 [SpdReg Kp Bypass] and 460 [SpdReg Ki Bypass]. To disable the
automatic gain calculation, set this parameter to a value of zero.
Note: This parameter was added for firmware version 6.001.

Default:

Min/Max:
Units:

10.0

0.0 / 100.0
rad / sec

Real

459

[SpdReg Kp Bypass]
The proportional gain (K

P

) of the speed regulator when an encoder or

tachometer feedback signal is changed to armature feedback (Par 458
[SpdReg FB Bypass] = 1 “Enabled”). This parameter can only be modified
when Par 448 [SpdReg BW Bypass] is set to zero.
Note: Units were changed from “%” to “none” for firmware revision 6.001.

Default:

Min/Max:

0.90 x P459

max

0.01 / Based on drive current rating

Real

458

460

[SpdReg Ki Bypass]
The integral gain (K

I

) of the speed regulator when an encoder or tachometer

feedback signal is changed to armature feedback (Par 458
[SpdReg FB Bypass] = 1 “Enabled”). This parameter can only be modified
when Par 448 [SpdReg BW Bypass] is set to zero.
Note: Units were changed from “%” to “sec

-1

” for firmware revision 6.001.

Default:

Min/Max:
Units:

0.30

0.00 / 100.00
sec

-1

Real

458

643

[SpdReg AntiBckup]
Allows control of over-shoot/under-shoot in the step response of the speed
regulator. Over-shoot/under-shoot can be effectively
eliminated with a setting of 0.3, which will remove backup of the motor shaft
when zero speed is reached. This parameter has no affect on the drive's
response to load changes. A value of zero disables this feature.
Note: This parameter was added for firmware version 4.001.

Default:

Min/Max:

0.0

0.0 / 0.50

Real

1016 [SpdFuncSelect]

Selection of the “Speed Up” or “Inertia/Loss compensation” function.
Notes: See Speed Up Function on page

320

for more information. Option 2

“Off” added for firmware version 4.001.

Default:

Options:

2 =

0 =
1 =
2 =

“Off”

“Speed Up”
“Inertia/loss”
“Off”

16-bit
Int

444,
445,
447,
1012,
1013,
1014,
1015