Figure 7, Figure 8 – Rockwell Automation 23P PowerFlex Digital DC Drive User Manual
Page 26
Advertising
![background image](/manuals/576962/26/background.png)
26
Rockwell Automation Publication 20P-UM001K-EN-P - July 2014
Chapter 1
Installation and Wiring
Figure 7 - Lift Frame C Drives
Figure 8 - Lift Frame D Drives
4.
Lift the drive into place onto the bolts that are installed in the panel.
5.
Install the remaining bolts into the panel. Tighten M8 bolts to a minimum
torque of 15 N
•
m (132.7 lb
•
in) and M10 bolts to a minimum torque of 25
N
•
m (221.2 lb
•
in).
Lifting flanges
Must be less
than 45° angle
Must be less
than 45° angle