MO

TO

R C

O

NT

ROL

Te

st

G

ene

rator

214

[SCR Diag Status]
Bits 0…11 indicate which SCR or SCR pair is in error. The type of error is indicated in bits 13…15. Only one type of error is shown at a time. The
precedence of errors is “Shorted SCR,” “OpenSCR Trip,” and “OpenSCR Warn.” Note that “OpenSCR Warn” is independent from a SCR trip configured as an
alarm. This parameter is only active when bit 0 “OpenSCR Tst” or bit 1 “ShortSCR Tst” of Par 213 is set to 1 “Enabled.” The SCR numbering shown is
SCR1…SCR6 for the forward power bridge and SCR11…SCR16 for the reverse bridge (regenerative drives only). In the standard drive, SCRx corresponds
to the SCR package labelled KGx and SCR1x to the package labelled KG0x. See the appropriate PowerFlex DC Drive Hardware Service Manual for your drive
frame size for instructions on replacing SCR modules. For frame A drives, see

20P-TG001

. For frame B drives, see

20P-TG002

. For frame C drives, see

20P-

TG003

. For frame D drives, see

20P-TG004

.

Note: This parameter was added for firmware version 6.001.

213,
215,
216,
217,
218

215

[OpenSCR WarnLvl]
Sets the open SCR warning level. This value determines when Par 214 [SCR
Diag Status], bit 13 “OpenSCR Warn” is set. This parameter is only active
when Par 213 [SCR Diag Test En], bit 0 “OpenSCR Tst” is enabled.
Note: This parameter was added for firmware version 6.001.

Default:

Min/Max:

1024

0 / 4096

16-bit
Int

213

216

[OpenSCR Flt Cfg]
Configures the open SCR error condition. This parameter is only active when
Par 213 [SCR Diag Test En], bit 0 “OpenSCR Tst” is enabled.
Note: This parameter was added for firmware version 6.001.

Default:

Options:

0 =

0 =
1 =
2 =

“Ignore”

“Ignore”
“Alarm”
“Fault”

16-bit
Int

213

217

[OpenSCR Threshld]
Sets the open SCR error level and when exceeded begins to accumulate. This
parameter is only active when Par 213 [SCR Diag Test En], bit 0 “OpenSCR Tst”
is enabled.
Note: This parameter was added for firmware version 6.001.

Default:

Min/Max:
Units:

50

0 / 100
%

16-bit
Int

213

218

[OpenSCR Trip Lvl]
Sets the open SCR trip level. The action taken by the drive when as open SCR
trip occurs is determined by Par 216 [OpenSCR Flt Cfg]. This parameter is only
active when Par 213 [SCR Diag Test En], bit 0 “OpenSCR Tst” is enabled.
Note: This parameter was added for firmware version 6.001.

Default:

Min/Max:

1024

0 / 4096

16-bit
Int

213,
216

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 114

for symbol descriptions

Values

Da

ta

T

yp

e

Rela

ted

A

Options

Shor

te

d SCR

Op

en

SC

R T

rip

Op

en

SC

R W

ar

n

Re

se

rv

ed

SCR

16

SCR

15

SCR

14

SCR

13

SCR

12

SCR

11

SCR

6

SCR

5

SCR

4

SCR

3

SCR

2

SCR

1

Default

0

0

0

x

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

A