Rockwell Automation 23P PowerFlex Digital DC Drive User Manual

Page 72

Advertising
background image

72

Rockwell Automation Publication 20P-UM001K-EN-P - July 2014

Chapter 1

Installation and Wiring

Table 23 - Frame D, Series B Heatsink Cooling Fan Terminal Designations

Table 24 - Frame D Heatsink Cooling Fan Signal Wire Sizes and Terminal Specifications

Figure 51 - Frame D Heatsink Cooling Fan Terminal Block Location

Terminal Block

Terminal

Description

AC Voltage

Max Current

U3

Three-phase AC input
power connections

400…460V AC
(50/60 Hz)

1.5 A

V3

W3

PE

Safety ground

31

Normally closed contact

250V AC

1 A

32

Terminals

Wire Size and Type

(1)

(1) See Cable and Wiring Recommendations on page

43

for more information.

Tightening Torque
N
m (lbin)

Flexible (mm

2

)

Multi-core (mm

2

)

AWG

U3, V3, W3, 31, 32, PE

0.14…1.5

0.14…2.5

28…12

0.5…0.6 (4.4…5.3)

U3 V3

W3 PE 31 32

U3 V3

W3 PE 31 32

Top View

of Drive

Series B terminal
block shown

Advertising
This manual is related to the following products: