Rockwell Automation 23P PowerFlex Digital DC Drive User Manual

Page 201

Advertising
background image

Rockwell Automation Publication 20P-UM001K-EN-P - July 2014

201

Programming and Parameters

Chapter 3

INPUT / OUT

P

UT

D

igi

tal

O

u

tpu

ts

581

[Dig Out Status]
Status of the standard digital outputs and relay outputs on the drive and on the optional I/O
Expansion circuit board (if present).

Read Only

629

[Relay Out 2 Sel]
Selects the source of the value that drives the N.O. relay between the
terminals 75 and 76.
See “Option Definitions” on page

200

.

Notes: Option 16 “Encoder Err” was changed for firmware version v5.002.
Options 30 and 31 were added for firmware version 6.001.

Default:

5 =

“Ready”

16-bit
Int

Options:

1267
1268
1269
1270
1271
1272
1273
1274

[Inversion Out 1]
[Inversion Out 2]
[Inversion Out 3]
[Inversion Out 4]
[Inversion Out 5]
[Inversion Out 6]
[Inversion Out 7]
[Inversion Out 8]
Reverses the digital output signal.

Default:

Options:

0 =

0 =
1 =

“Disabled”

“Disabled”
“Enabled”

16-bit
Int

1275

[Inversion Relay2]
Inverts the signal for Relay Output 2.

Default:

Options:

0 =

0 =
1 =

“Disabled”

“Disabled”
“Enabled”

16-bit
Int

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 114

for symbol descriptions

Values

Da

ta

T

yp

e

Rela

ted

Options

Rela

y O

ut2

Rela

y O

ut1

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Digital O

ut8

Digital O

ut7

Digital O

ut6

Digital O

ut5

Digital O

ut4

Digital O

ut3

Digital O

ut2

Digital O

ut1

Default

0

0

x

x

x

x

x

x

0

0

0

0

0

0

0

0

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

0 =

“Not Used” (Off)

8 =

“Spd Limited”

16 = “Spd Fdbk Err”

24 = “ContactDB”

1 =

“Spd Zero Thr”

9 =

“Fault”

17 = “Diam Calc”

25 = “Contactor”

2 =

“Spd Thresh”

10 = “Power Loss”

18 = “Input1 Cmp”

26 = “Alarm”

3 =

“At Speed”

11 =

“UserDefinedA”

19 = “Diam Reached”

27 = “Running”

4 =

“CurrentLimit”

12 =

“UserDefinedB”

20 = “Speed Match”

28 = “Jogging”

5 =

“Ready”

13 = “Stop Control”

21 = “Accelerating”

29 = “Active”

6 =

“Ramp Pos”

14 = “Field Loss”

22 = “Decelerating”

30 = “Brake Slip”

7 =

“Ramp Neg”

15 =

“Spd Fbk Loss”

23 = “Brake Cmd”

31 = “TP Brake Cmd”